产品标题
Calculated volume or mass flow measurement. dp primary element (orifice).
Orifice meter run with annular chamber corner taps. -
传感器特点
Internationally standardized.
Including pipe section.
Small pipe sizes DN10...50 ; 3/8...2".
Exchangeable orifice plate.
Compact or remote design.
Optimizable for minimized pressure loss, improved uncertainty or maximized Turndown.
Deltabar S/M differential pressure transmitter. -
公称口径范围
DN 10...50
3/8" ... 2" -
最大测量误差
typically < 1,5% of calculated volume or mass.
DN < 25 / 1" calibration recommended. -
测量范围
0.02 ... 40m3/h
-
最大过程压力
PN6 ... 160
Cl.150 ... 2500 -
介质温度范围
Compact version:
-200°C ... 200°C
-328°F ... 392°F
Remote version:
-200°C ... 1000°C
-328°F ... 1832°F -
防护等级
Transmitter (Deltabar):
IP67
NEMA6P -
显示/操作
Transmitter (Deltabar):
4-line display
3 push buttons
Quick setup
HistoROM -
输出
Transmitter (Deltabar):
4 ... 20 mA -
数字通信
Transmitter (Deltabar):
HART
PROFIBUS PA
FOUNDATION Fieldbus -
防爆认证
Transmitter (Deltabar):
ATEX
FM
CSA
IEC
TIIS
NEPSI
-
产品标题
Calculated volume or mass flow measurement. dp primary element (orifice).
Orifice meter run with annular chamber corner taps. -
传感器特点
Internationally standardized.
Including pipe section.
Small pipe sizes DN10...50 ; 3/8...2".
Exchangeable orifice plate.
Compact or remote design.
Optimizable for minimized pressure loss, improved uncertainty or maximized Turndown.
Deltabar S/M differential pressure transmitter. -
公称口径范围
DN 10...50
3/8" ... 2" -
最大测量误差
typically < 1,5% of calculated volume or mass.
DN < 25 / 1" calibration recommended.
Uncertainty of primary element excluding uncertainty of density or compensation. -
测量范围
0.4 ... 550m3/h
-
最大过程压力
PN6 ... 160
Cl.150 ... 2500 -
介质温度范围
Compact version:
-200°C ... 200°C
-328°F ... 392°F
Remote version:
-200°C ... 1000°C
-328°F ... 1832°F -
防护等级
Transmitter (Deltabar):
IP67
NEMA6P -
显示/操作
Transmitter (Deltabar):
4-line display
3 push buttons
Quick setup
HistoROM -
输出
Transmitter (Deltabar):
4 ... 20 mA -
数字通信
Transmitter (Deltabar):
HART
PROFIBUS PA
FOUNDATION Fieldbus -
防爆认证
Transmitter (Deltabar):
ATEX
FM
CSA
IEC
TIIS
NEPSI
-
产品标题
Calculated volume or mass flow measurement. dp primary element (orifice).
Orifice meter run with annular chamber corner taps. -
传感器特点
Internationally standardized.
Including pipe section.
Small pipe sizes DN10...50 ; 3/8...2".
Exchangeable orifice plate.
Compact or remote design.
Optimizable for minimized pressure loss, improved uncertainty or maximized Turndown.
Deltabar S/M differential pressure transmitter. -
公称口径范围
DN 10...50
3/8" ... 2" -
最大测量误差
typically < 1,5% of calculated volume or mass.
DN < 25 / 1" calibration recommended.
Uncertainty of primary element excluding uncertainty of density or compensation. -
测量范围
0.4 ... 550m3/h
2.0 ... 2750 kg/h at 10bar/230°C -
最大过程压力
PN6 ... 160
Cl.150 ... 2500 -
介质温度范围
Compact version:
-200°C ... 200°C
-328°F ... 392°F
Remote version:
-200°C ... 1000°C
-328°F ... 1832°F -
防护等级
Transmitter (Deltabar):
IP67
NEMA6P -
显示/操作
Transmitter (Deltabar):
4-line display
3 push buttons
Quick setup
HistoROM -
输出
Transmitter (Deltabar):
4 ... 20 mA -
数字通信
Transmitter (Deltabar):
HART
PROFIBUS PA
FOUNDATION Fieldbus -
防爆认证
Transmitter (Deltabar):
ATEX
FM
CSA
IEC
TIIS
NEPSI