Boost chlorine reliability with electromagnetic flowmeters

How Olin Corporation improved its electrolysis process with Proline Promag P 300 of Endress+Hauser

When Olin's Plaquemine, Louisiana (USA) chlorine facility needed a fix for unreliable flow measurements caused by extreme electrical interference, they turned to Endress+Hauser for accurate electromagnetic flowmeter readings. Proline Promag P 300 with floating measurement technology reduced susceptibility to stray currents and interference enabling immediate improvements in measurement stability, process control, safety and operational confidence.

Endress+Hauser's Proline Promag P 300 ©Endress+Hauser

Olin’s Plaquemine chlorine production facility benefits from accurate flow readings from the electromagnetic flowmeter Proline Promag P 300 despite high stray currents and interference

Stable, accurate flow measurement for every phase

  • Immediate improvements in measurement stability, process control, safety and operational confidence

  • Reduced cost and reduced risk of leaks or failures by eliminating the need for grounding rings

  • Process efficiency through accurate flow data across all operational phases, even in the face of extreme electrical interference

  • Reduced downtime due to the elimination of erratic readings and false alarms

  • Lower maintenance costs due to less shutdowns, high corrosion-resistance and no mechanical components in the measuring tube

Picture of Michael Beck, Instrument Technology Leader

"We try to order every flowmeter with Heartbeat Technology. We're excited about the additional insights we'll be able to gain."

Michael Beck, Instrument Technology Leader
Olin Corporation

Challenges solved using electromagnetic flowmeter principle

In Olin’s chlorine production process, flow measurement is critical: insufficient flow can prevent proper chemical mixing, reduce efficiency and trigger alarms or shutdowns. The Plaquemine facility faced persistent challenges with electromagnetic flowmeters in its high-voltage environment (up to 850 volts DC and 72,000 amps). They struggled with erratic flow readings caused by stray currents and potentially damaged grounding electrodes. Operators had to rely on workarounds and endure costly inefficiencies.

Electromagnetic flowmeter tech cuts stray current risks

To address these challenges, Olin collaborated with Endress+Hauser to trial the Proline Promag P 300 electromagnetic flowmeter equipped with floating measurement technology. This innovative design eliminates the need for traditional grounding rings, significantly reducing susceptibility to stray currents and interference. Promag P 300 withstands harsh conditions and delivers the accuracy, reliability and confidence Olin needed to optimize its processes and plan for the future.

  • 简易产品

  • 轻松执行仪表选型、安装和操作

仪表技术性能

选型便捷程度

  • 标准产品

  • 测量可靠、坚固耐用、低维护需求

仪表技术性能

选型便捷程度

  • 高端产品

  • 功能丰富,适用范围广

仪表技术性能

选型便捷程度

  • 定制产品

  • 专门针对严苛工况设计

仪表技术性能

选型便捷程度

特殊选型

FLEX产品选型 仪表技术性能 选型便捷程度
  • F
  • L
  • E
  • X

Fundamental选型

完美胜任基本测量任务

仪表技术性能
选型便捷程度
  • F
  • L
  • E
  • X

Lean选型

轻松应对关键工艺的测量挑战

仪表技术性能
选型便捷程度
  • F
  • L
  • E
  • X

Extended选型

创新技术助力工艺流程优化

仪表技术性能
选型便捷程度
  • F
  • L
  • E
  • X

Xpert选型

满足严苛工况的特殊测量要求

仪表技术性能
选型便捷程度

特殊选型